Preview

Doklady BGUIR

Advanced search

Data processing of non-stationary capillary viscometer for blood

Abstract

The work is devoted to the development of the theoretical foundations of the processing of measurement results and the algorithm for processing the results for automating measurements for a non-stationary capillary viscometer. The proposed algorithm allows achieving measurement performance and obtaining hemorheological data for diagnostic purposes with a satisfactory degree of accuracy. The results obtained with use of non-stationary capillary viscometer are compared with results achieved with use of rotational viscometer.

About the Authors

V. G. Leshchenko
Белорусский государственный медицинский университет, Республика Беларусь
Belarus


M. V. Goltsev
Белорусский государственный медицинский университет, Республика Беларусь
Belarus


D. V. Mansurov
Белорусский государственный медицинский университет, Республика Беларусь
Belarus


V. A. Mansurov
Белорусский государственный медицинский университет, Республика Беларусь
Belarus


References

1. Baskurt K. Pathophysiological Significance of Blood Rheology // Turk. J Med Sci. 2003. Vol. 33. P. 347-355. 2. Determination of the blood viscosity and yield stress with a pressure- scanning capillary hemorheometer using constitutive models / Byung-Kwon Lee [et al.] // Korea-Australia Rheology Journal. March 2011. Vol. 23, No. 1. P. 1-6. 3. Kensey Kenneth, Hogenauer William N., Kim Sangho, Cho Young. Dual riser/single capillary viscometer / U.S. Patent № 6,745,615. 4. Митьковская Н.П., Герасименок Д.С., Лещенко В.Г., Гольцев М.В., Мансуров Д.В., Мансуров В.А. Устройство для определения гемореологических индексов / Пат. Республики Беларусь № 11640. 5. Тихонов А.Н., Арсенин В.Я. Методы решения некорректных задач. М.: Наука, 1979. 283 с

2. Baskurt K. Pathophysiological Significance of Blood Rheology // Turk. J Med Sci. 2003. Vol. 33. P. 347-355. 2. Determination of the blood viscosity and yield stress with a pressure- scanning capillary hemorheometer using constitutive models / Byung-Kwon Lee [et al.] // Korea-Australia Rheology Journal. March 2011. Vol. 23, No. 1. P. 1-6. 3. Kensey Kenneth, Hogenauer William N., Kim Sangho, Cho Young. Dual riser/single capillary viscometer / U.S. Patent № 6,745,615. 4. Митьковская Н.П., Герасименок Д.С., Лещенко В.Г., Гольцев М.В., Мансуров Д.В., Мансуров В.А. Устройство для определения гемореологических индексов / Пат. Республики Беларусь № 11640. 5. Тихонов А.Н., Арсенин В.Я. Методы решения некорректных задач. М.: Наука, 1979. 283 с

3. Baskurt K. Pathophysiological Significance of Blood Rheology // Turk. J Med Sci. 2003. Vol. 33. P. 347-355.

4. Determination of the blood viscosity and yield stress with a pressure- scanning capillary hemorheometer using constitutive models / Byung-Kwon Lee [et al.] // Korea-Australia Rheology Journal. March 2011. Vol. 23, No. 1. P. 1-6.

5. Kensey Kenneth, Hogenauer William N., Kim Sangho, Cho Young. Dual riser/single capillary viscometer / U.S. Patent № 6,745,615.

6. Митьковская Н.П., Герасименок Д.С., Лещенко В.Г., Гольцев М.В., Мансуров Д.В., Мансуров В.А. Устройство для определения гемореологических индексов / Пат. Республики Беларусь № 11640.

7. Тихонов А.Н., Арсенин В.Я. Методы решения некорректных задач. М.: Наука, 1979. 283 с.


Review

For citations:


Leshchenko V.G., Goltsev M.V., Mansurov D.V., Mansurov V.A. Data processing of non-stationary capillary viscometer for blood. Doklady BGUIR. 2018;(7):30-35. (In Russ.)

Views: 1446