<?xml version="1.0" encoding="UTF-8"?>
<!DOCTYPE article PUBLIC "-//NLM//DTD JATS (Z39.96) Journal Publishing DTD v1.3 20210610//EN" "JATS-journalpublishing1-3.dtd">
<article article-type="research-article" dtd-version="1.3" xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xml:lang="ru"><front><journal-meta><journal-id journal-id-type="publisher-id">bsuir</journal-id><journal-title-group><journal-title xml:lang="ru">Доклады БГУИР</journal-title><trans-title-group xml:lang="en"><trans-title>Doklady BGUIR</trans-title></trans-title-group></journal-title-group><issn pub-type="ppub">1729-7648</issn><issn pub-type="epub">2708-0382</issn><publisher><publisher-name>БГУИР</publisher-name></publisher></journal-meta><article-meta><article-id custom-type="elpub" pub-id-type="custom">bsuir-1037</article-id><article-categories><subj-group subj-group-type="heading"><subject>Research Article</subject></subj-group><subj-group subj-group-type="section-heading" xml:lang="ru"><subject>УГЛЕРОДОСОДЕРЖАЩИЕ ЭКРАНЫ ДЛЯ ЗАЩИТЫ ОРГАНИЗМА ЧЕЛОВЕКА ОТ ЭЛЕКТРОМАГНИТНОГО ИЗЛУЧЕНИЯ</subject></subj-group></article-categories><title-group><article-title>НЕСТАЦИОНАРНЫЙ КАПИЛЛЯРНЫЙ ВИСКОЗИМЕТР ДЛЯ КРОВИ</article-title><trans-title-group xml:lang="en"><trans-title>Data processing of non-stationary capillary viscometer for blood</trans-title></trans-title-group></title-group><contrib-group><contrib contrib-type="author" corresp="yes"><name-alternatives><name name-style="eastern" xml:lang="ru"><surname>Лещенко</surname><given-names>В. Г.</given-names></name><name name-style="western" xml:lang="en"><surname>Leshchenko</surname><given-names>V. G.</given-names></name></name-alternatives><email xlink:type="simple">noemail@neicon.ru</email><xref ref-type="aff" rid="aff-1"/></contrib><contrib contrib-type="author" corresp="yes"><name-alternatives><name name-style="eastern" xml:lang="ru"><surname>Гольцев</surname><given-names>М. В.</given-names></name><name name-style="western" xml:lang="en"><surname>Goltsev</surname><given-names>M. V.</given-names></name></name-alternatives><email xlink:type="simple">noemail@neicon.ru</email><xref ref-type="aff" rid="aff-1"/></contrib><contrib contrib-type="author" corresp="yes"><name-alternatives><name name-style="eastern" xml:lang="ru"><surname>Мансуров</surname><given-names>Д. В.</given-names></name><name name-style="western" xml:lang="en"><surname>Mansurov</surname><given-names>D. V.</given-names></name></name-alternatives><email xlink:type="simple">mansurov@tut.by</email><xref ref-type="aff" rid="aff-1"/></contrib><contrib contrib-type="author" corresp="yes"><name-alternatives><name name-style="eastern" xml:lang="ru"><surname>Мансуров</surname><given-names>В. А.</given-names></name><name name-style="western" xml:lang="en"><surname>Mansurov</surname><given-names>V. A.</given-names></name></name-alternatives><email xlink:type="simple">mansurov@tut.by</email><xref ref-type="aff" rid="aff-1"/></contrib></contrib-group><aff xml:lang="ru" id="aff-1"><institution>Белорусский государственный медицинский университет, Республика Беларусь</institution><country>Belarus</country></aff><pub-date pub-type="collection"><year>2018</year></pub-date><pub-date pub-type="epub"><day>03</day><month>06</month><year>2019</year></pub-date><volume>0</volume><issue>7</issue><fpage>30</fpage><lpage>35</lpage><permissions><copyright-statement>Copyright &amp;#x00A9; Лещенко В.Г., Гольцев М.В., Мансуров Д.В., Мансуров В.А., 2019</copyright-statement><copyright-year>2019</copyright-year><copyright-holder xml:lang="ru">Лещенко В.Г., Гольцев М.В., Мансуров Д.В., Мансуров В.А.</copyright-holder><copyright-holder xml:lang="en">Leshchenko V.G., Goltsev M.V., Mansurov D.V., Mansurov V.A.</copyright-holder><license xml:lang="ru" license-type="creative-commons-attribution" xlink:href="https://creativecommons.org/licenses/by/4.0/" xlink:type="simple"><license-p>Данная работа распространяется под лицензией Creative Commons Attribution 4.0.</license-p></license><license xml:lang="en" license-type="creative-commons-attribution" xlink:href="https://creativecommons.org/licenses/by/4.0/" xlink:type="simple"><license-p>This work is licensed under a Creative Commons Attribution 4.0 License.</license-p></license></permissions><self-uri xlink:href="https://doklady.bsuir.by/jour/article/view/1037">https://doklady.bsuir.by/jour/article/view/1037</self-uri><abstract><p>Работа посвящается разработке теоретических основ обработки результатов измерений и алгоритма обработки результатов для автоматизации измерений для нестационарного капиллярного вискозиметра. Предложенный алгоритм позволяет достичь быстродействия измерений и получить гемореологические данные для диагностических целей с удовлетворительной степенью точности. Приводится сравнение результатов, полученных при использовании нестационарного капиллярного вискозиметра, c результатами, достигнутыми при использовании стандартного ротационного вискозиметра.</p></abstract><trans-abstract xml:lang="en"><p>The work is devoted to the development of the theoretical foundations of the processing of measurement results and the algorithm for processing the results for automating measurements for a non-stationary capillary viscometer. The proposed algorithm allows achieving measurement performance and obtaining hemorheological data for diagnostic purposes with a satisfactory degree of accuracy. The results obtained with use of non-stationary capillary viscometer are compared with results achieved with use of rotational viscometer.</p></trans-abstract><kwd-group xml:lang="ru"><kwd>нестационарный капиллярный вискозиметр</kwd><kwd>алгоритм обработки результатов реологические свойства крови</kwd></kwd-group><kwd-group xml:lang="en"><kwd>non-stationary capillary viscometer</kwd><kwd>processing of measurement results</kwd><kwd>rheological properties of blood</kwd></kwd-group></article-meta></front><back><ref-list><title>References</title><ref id="cit1"><label>1</label><citation-alternatives><mixed-citation xml:lang="ru">Baskurt K. Pathophysiological Significance of Blood Rheology // Turk. J Med Sci. 2003. Vol. 33. P. 347-355. 2. Determination of the blood viscosity and yield stress with a pressure- scanning capillary hemorheometer using constitutive models / Byung-Kwon Lee [et al.] // Korea-Australia Rheology Journal. March 2011. Vol. 23, No. 1. P. 1-6. 3. Kensey Kenneth, Hogenauer William N., Kim Sangho, Cho Young. Dual riser/single capillary viscometer / U.S. Patent № 6,745,615. 4. Митьковская Н.П., Герасименок Д.С., Лещенко В.Г., Гольцев М.В., Мансуров Д.В., Мансуров В.А. Устройство для определения гемореологических индексов / Пат. Республики Беларусь № 11640. 5. Тихонов А.Н., Арсенин В.Я. Методы решения некорректных задач. М.: Наука, 1979. 283 с</mixed-citation><mixed-citation xml:lang="en">Baskurt K. Pathophysiological Significance of Blood Rheology // Turk. J Med Sci. 2003. Vol. 33. P. 347-355. 2. Determination of the blood viscosity and yield stress with a pressure- scanning capillary hemorheometer using constitutive models / Byung-Kwon Lee [et al.] // Korea-Australia Rheology Journal. March 2011. Vol. 23, No. 1. P. 1-6. 3. Kensey Kenneth, Hogenauer William N., Kim Sangho, Cho Young. Dual riser/single capillary viscometer / U.S. Patent № 6,745,615. 4. Митьковская Н.П., Герасименок Д.С., Лещенко В.Г., Гольцев М.В., Мансуров Д.В., Мансуров В.А. Устройство для определения гемореологических индексов / Пат. Республики Беларусь № 11640. 5. Тихонов А.Н., Арсенин В.Я. Методы решения некорректных задач. М.: Наука, 1979. 283 с</mixed-citation></citation-alternatives></ref><ref id="cit2"><label>2</label><citation-alternatives><mixed-citation xml:lang="ru">Baskurt K. Pathophysiological Significance of Blood Rheology // Turk. J Med Sci. 2003. Vol. 33. P. 347-355. 2. Determination of the blood viscosity and yield stress with a pressure- scanning capillary hemorheometer using constitutive models / Byung-Kwon Lee [et al.] // Korea-Australia Rheology Journal. March 2011. Vol. 23, No. 1. P. 1-6. 3. Kensey Kenneth, Hogenauer William N., Kim Sangho, Cho Young. Dual riser/single capillary viscometer / U.S. Patent № 6,745,615. 4. Митьковская Н.П., Герасименок Д.С., Лещенко В.Г., Гольцев М.В., Мансуров Д.В., Мансуров В.А. Устройство для определения гемореологических индексов / Пат. Республики Беларусь № 11640. 5. Тихонов А.Н., Арсенин В.Я. Методы решения некорректных задач. М.: Наука, 1979. 283 с</mixed-citation><mixed-citation xml:lang="en">Baskurt K. Pathophysiological Significance of Blood Rheology // Turk. J Med Sci. 2003. Vol. 33. P. 347-355. 2. Determination of the blood viscosity and yield stress with a pressure- scanning capillary hemorheometer using constitutive models / Byung-Kwon Lee [et al.] // Korea-Australia Rheology Journal. March 2011. Vol. 23, No. 1. P. 1-6. 3. Kensey Kenneth, Hogenauer William N., Kim Sangho, Cho Young. Dual riser/single capillary viscometer / U.S. Patent № 6,745,615. 4. Митьковская Н.П., Герасименок Д.С., Лещенко В.Г., Гольцев М.В., Мансуров Д.В., Мансуров В.А. Устройство для определения гемореологических индексов / Пат. Республики Беларусь № 11640. 5. Тихонов А.Н., Арсенин В.Я. Методы решения некорректных задач. М.: Наука, 1979. 283 с</mixed-citation></citation-alternatives></ref><ref id="cit3"><label>3</label><citation-alternatives><mixed-citation xml:lang="ru">Baskurt K. Pathophysiological Significance of Blood Rheology // Turk. J Med Sci. 2003. Vol. 33. P. 347-355.</mixed-citation><mixed-citation xml:lang="en">Baskurt K. Pathophysiological Significance of Blood Rheology // Turk. J Med Sci. 2003. Vol. 33. P. 347-355.</mixed-citation></citation-alternatives></ref><ref id="cit4"><label>4</label><citation-alternatives><mixed-citation xml:lang="ru">Determination of the blood viscosity and yield stress with a pressure- scanning capillary hemorheometer using constitutive models / Byung-Kwon Lee [et al.] // Korea-Australia Rheology Journal. March 2011. Vol. 23, No. 1. P. 1-6.</mixed-citation><mixed-citation xml:lang="en">Determination of the blood viscosity and yield stress with a pressure- scanning capillary hemorheometer using constitutive models / Byung-Kwon Lee [et al.] // Korea-Australia Rheology Journal. March 2011. Vol. 23, No. 1. P. 1-6.</mixed-citation></citation-alternatives></ref><ref id="cit5"><label>5</label><citation-alternatives><mixed-citation xml:lang="ru">Kensey Kenneth, Hogenauer William N., Kim Sangho, Cho Young. Dual riser/single capillary viscometer / U.S. Patent № 6,745,615.</mixed-citation><mixed-citation xml:lang="en">Kensey Kenneth, Hogenauer William N., Kim Sangho, Cho Young. Dual riser/single capillary viscometer / U.S. Patent № 6,745,615.</mixed-citation></citation-alternatives></ref><ref id="cit6"><label>6</label><citation-alternatives><mixed-citation xml:lang="ru">Митьковская Н.П., Герасименок Д.С., Лещенко В.Г., Гольцев М.В., Мансуров Д.В., Мансуров В.А. Устройство для определения гемореологических индексов / Пат. Республики Беларусь № 11640.</mixed-citation><mixed-citation xml:lang="en">Митьковская Н.П., Герасименок Д.С., Лещенко В.Г., Гольцев М.В., Мансуров Д.В., Мансуров В.А. Устройство для определения гемореологических индексов / Пат. Республики Беларусь № 11640.</mixed-citation></citation-alternatives></ref><ref id="cit7"><label>7</label><citation-alternatives><mixed-citation xml:lang="ru">Тихонов А.Н., Арсенин В.Я. Методы решения некорректных задач. М.: Наука, 1979. 283 с.</mixed-citation><mixed-citation xml:lang="en">Тихонов А.Н., Арсенин В.Я. Методы решения некорректных задач. М.: Наука, 1979. 283 с.</mixed-citation></citation-alternatives></ref></ref-list><fn-group><fn fn-type="conflict"><p>The authors declare that there are no conflicts of interest present.</p></fn></fn-group></back></article>
