Preview

Doklady BGUIR

Advanced search

THE STUDY OF LOW-INTENSITY PULSED ULTRASOUND INFLUENCE ON WETTABILITY OF TITANIUM DENTAL IMPLANTS’ SURFACE IN EXPERIMENTAL MODEL

Abstract

The results of experimental studies, the purpose of which was to study the effect of low-intensity pulsed ultrasound on the wettability of the surface of titanium dental implants are described. We studied 64 titanium dental implants. The control group consisted of 32 dental implants without ultra-sonication. The experimental group consisted of 32 dental implants, which were exposed to low-intensity pulsed ultrasound. Studies using low-intensity pulsed ultrasound showed that the wettability of the surface of all the experimental samples (32 dental implant) was 100 %, and the wettability of control samples (32 dental implant) was not observed. Thus the previously unknown property of low intensity pulsed ultrasound enabling the wetting of entire surface of the dental implant was discovered.

About the Authors

S. P. Rubnikovich
Белорусская медицинская академия последипломного образования
Belarus


I. S. Khomich
Белорусская медицинская академия последипломного образования
Belarus


V. T. Minchenya
Белорусский национальный технический университет
Belarus


References

1. Рубникович С.П. // Стоматолог. Минск. 2015. № 3 (18). С. 29-36.

2. Рубникович С.П., Хомич И.С. // Стоматолог. Минск. 2014. № 1(12). С. 77-86.

3. Рубникович С.П., Хомич И.С. // Стоматолог. Минск. 2014. № 4 (15). С. 56-57.

4. Хомич И.С., Рубникович С.П., Хомич С.Ф. // Стоматолог. Минск. 2014. № 2(13). С. 11-18.

5. Хомич И.С., Рубникович С.П., Хомич С.Ф. // Стоматолог. Минск. 2014. № 3 (14). С. 67-69.

6. Pjetursson B.E., Bragger U., Lang N.P. et. al. // Clin Oral Implants Res. 2007. № 18. P. 97-113.

7. Takeshita F., Murai K., Iyama S. et. al. // J. Periodontol. 1998. № 69. P. 314-320

8. Van Steenberghe D., Jacobs R., Desnyder M. et. al. // Clin Oral Implants Res. 2002. № 13. P. 617-622

9. Moy P.K., Medina D., Shetty V. et. al. // Int J Oral Maxillofac Implants. 2005. № 20. P. 569-577.

10. LeGeros R.Z., Craig R.G. // J. Bone Miner Res. 1993. № 8. P. 583-596.

11. Wennerberg A., Albrektsson T. // Int J. Oral Maxillofac Implants. 2010. № 25. P. 63-74.

12. Anil S., Alghamdi H., Jansen J.A. Implant Dentistry - A Rapidly Evolving Practice. InTech, Rijeka, 2011. P. 83-108

13. Branemark P.I. // Scand J Clin Lab Invest. 1959. № 11. P. 1-82.

14. Потенциал современной науки. 2015. № 5. C. 21-23.

15. Thevenot P, Hu W, Tang L. // Current topics in medicinal chemistry. 2008. № 8. P. 270-280.

16. Rupp F., Scheideler L., Eichler M. et. al. // Int J. Oral Maxillofac Implants. 2011. № 26. P. 1256-1266.


Review

For citations:


Rubnikovich S.P., Khomich I.S., Minchenya V.T. THE STUDY OF LOW-INTENSITY PULSED ULTRASOUND INFLUENCE ON WETTABILITY OF TITANIUM DENTAL IMPLANTS’ SURFACE IN EXPERIMENTAL MODEL. Doklady BGUIR. 2016;(7):2013-2017. (In Russ.)

Views: 405


Creative Commons License
This work is licensed under a Creative Commons Attribution 4.0 License.


ISSN 1729-7648 (Print)