Improving the accuracy and metrological support of power meters in the frequency range from 37.5 to 178.6 GHz
https://doi.org/10.35596/1729-7648-2021-19-3-81-88
Abstract
To satisfy the needs for metrological support of power measurements in the frequency range from 37.5 to 178.6 GHz, the device has been developed and designed for automated measurements, calibrations and verification of wattmeters with high accuracy and the ability to adapt to various types of devices under investigation. This paper presents the composition, diagram andgeneral principle of the device. A description of the structure of isothermal calorimetric converters of autocompensation type with dry load and reference body, which are the basis of the device, is given. The implemented algorithms for converting and replacing microwave power with direct current power of the developed calorimetric wattmeters are presented. The measures taken at the manufacturing stage to minimize sources of measurement uncertainty are described. To assess the accuracy of measuring the absorbed power, a mathematical model of the conversion factor has been compiled. Corrections have been introduced into this mathematical model to improve the measurement accuracy of the reproducible microwave power. The obtained basic metrological and technical characteristics of calorimetric wattmeters and comparison equipment of the device are presented. The obtained metrological and technical characteristics correspond to the current level of standard equipment.
About the Authors
A. V. GusinskyBelarus
GusinskyAlexander Vladimirovic, PhD, Associate Professor, Head of the Center 1.9 of R&D Department
220013, Minsk, P. Brovka str., 6
tel. +375-17-293-84-42
M. M. Kasperovich
Belarus
M.Sc, Researcher of the Center 1.9 of R&D Department
220013, Minsk, P. Brovka str., 6
tel. +375-17-293-84-42
V. A. Bogush
Belarus
D.Sc., Professor, Rector
220013, Minsk, P. Brovka str., 6
tel. +375-17-293-84-42
References
1. Gusinsky A.V. [Measuring complex of testing and calibration of power meters in the millimeter range of waves length]. Doklady BGUIR = Doklady BGUIR. 2019;6(124):50-54. (In Russ.)
2. Luferov A.N., Gusinsky A.V., Kostrikin A.M., Voroshen A.V., Gursky S.S., Bozhenkov V.V., Deryabina M.Yu., Gursky A.L. [Measuring complex for verification and calibration of power meters in the frequency range 78.33 – 118.1 GHz]. Standardization.2014;3:50-53. (In Russ.)
3. Bilko M.I., Tomashevsky A.K. [Microwave power measurement]. Moscow: Radio i svjaz'; 1986. (In Russ.)
4. Akhiezer A.N., Danilchenko V.P., Senko A.P., Terekhov M.V., Gordeev K.K., Kaliberda L.G., Terzhova V.P. [State special standard for the unit of power of electromagnetic oscillations in waveguide paths in the frequency range 53.57 – 78.33 GHz]. Izmeritel'naya tekhnika. 1979;7:3-5. (In Russ.)
5. Burak I.F., Gusinsky A.V., Sharov G.A., Voroshen A.V., Luferov A.N. [Measurement of microwave power in the range of centimeter and millimeter waves]. Moscow: Goryachaya liniya – Telekom; 2018. (In Russ.)
6. Fantom A. Radio Frequency and Microwave Power Measurement. London: Peter Peregrinus Ltd.; 1990.
Review
For citations:
Gusinsky A.V., Kasperovich M.M., Bogush V.A. Improving the accuracy and metrological support of power meters in the frequency range from 37.5 to 178.6 GHz. Doklady BGUIR. 2021;19(3):81-88. (In Russ.) https://doi.org/10.35596/1729-7648-2021-19-3-81-88