REQUIRED AND SUFFICIENT LEVEL OF GSM BASE STATIONS ELECTROMAGNETIC RADIATION POWER

Abstract

Estimations of levels of the equivalent isotropic radiated power in frequency channels of GSM 900/1800 base stations (BS) which are required and sufficient for the effective utilization of radio-frequency resource allocated to the GSM network, are resulted. Analysis is performed for various BS antenna heights, various population density, various levels of real sensitivity of BS radio reception, various cluster dimension of GSM network frequency planning and different specific traffic intensity.

About the Authors

V. I. Mordachev
Белорусский государственный университет информатики и радиоэлектроники
Belarus


A. S. Svistunov
Белорусский государственный университет информатики и радиоэлектроники
Belarus


References

1. СанПиГН «Гигиенические требования к установке и эксплуатации систем сотовой связи».

2. Оценка риска для здоровья населения от воздействия электромагнитных полей, создаваемых базовыми станциями сотовой подвижной электросвязи и широкополосного беспроводного доступа. Инструкция по применению.

3. Мордачев В.И. Системная экология сотовой радиосвязи. Минск, 2009.

4. Мордачев В.И., Свистунов А.С. // Докл. БГУИР. 2010. № 8(54). С. 46-53.

5. Мордачев В.И., Свистунов А.С. // Докл. БГУИР. 2011. № 7(61). С. 15-22.

6. Recommendation ITU-R P.529-3.

7. Asha Mehrotra. Cellular Radio: Analog and Digital Systems. Artech House Publishers. London, 1994.

8. Recommendation ITU-R M.1390.

9. Мордачев В.И. // Докл. БГУИР. 2012. № 6 (68). С. 116-123.