<?xml version="1.0" encoding="UTF-8"?>
<!DOCTYPE article PUBLIC "-//NLM//DTD JATS (Z39.96) Journal Publishing DTD v1.3 20210610//EN" "JATS-journalpublishing1-3.dtd">
<article article-type="research-article" dtd-version="1.3" xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xml:lang="ru"><front><journal-meta><journal-id journal-id-type="publisher-id">bsuir</journal-id><journal-title-group><journal-title xml:lang="ru">Доклады БГУИР</journal-title><trans-title-group xml:lang="en"><trans-title>Doklady BGUIR</trans-title></trans-title-group></journal-title-group><issn pub-type="ppub">1729-7648</issn><issn pub-type="epub">2708-0382</issn><publisher><publisher-name>БГУИР</publisher-name></publisher></journal-meta><article-meta><article-id custom-type="elpub" pub-id-type="custom">bsuir-784</article-id><article-categories><subj-group subj-group-type="heading"><subject>Research Article</subject></subj-group><subj-group subj-group-type="section-heading" xml:lang="ru"><subject>Статьи</subject></subj-group></article-categories><title-group><article-title>ПРОГРАММА КОНТРОЛЯ КАЧЕСТВА ДЛЯ ПОЗИТРОННО-ЭМИССИОННОГО ТОМОГРАФА СОВМЕЩЕННОГО С КОМПЬЮТЕРНЫМ ТОМОГРАФОМ</article-title><trans-title-group xml:lang="en"><trans-title>QUALITY CONTROL PROGRAM FOR POSITRON EMISSION TOMOGRAPH COMBINED WITH COMPUTER TOMOGRAPH</trans-title></trans-title-group></title-group><contrib-group><contrib contrib-type="author" corresp="yes"><name-alternatives><name name-style="eastern" xml:lang="ru"><surname>Емельяненко</surname><given-names>Е. Е.</given-names></name><name name-style="western" xml:lang="en"><surname>Emelyanenko</surname><given-names>E. E.</given-names></name></name-alternatives><email xlink:type="simple">noemail@neicon.ru</email><xref ref-type="aff" rid="aff-1"/></contrib><contrib contrib-type="author" corresp="yes"><name-alternatives><name name-style="eastern" xml:lang="ru"><surname>Тарутин</surname><given-names>И. Г.</given-names></name><name name-style="western" xml:lang="en"><surname>Tarutin</surname><given-names>I. G.</given-names></name></name-alternatives><email xlink:type="simple">noemail@neicon.ru</email><xref ref-type="aff" rid="aff-1"/></contrib><contrib contrib-type="author" corresp="yes"><name-alternatives><name name-style="eastern" xml:lang="ru"><surname>Савков</surname><given-names>А. В.</given-names></name><name name-style="western" xml:lang="en"><surname>Savkov</surname><given-names>A. V.</given-names></name></name-alternatives><email xlink:type="simple">noemail@neicon.ru</email><xref ref-type="aff" rid="aff-1"/></contrib></contrib-group><aff xml:lang="ru" id="aff-1"><institution>РНПЦ онкологии и медицинской радиологии им. Н.Н. Александрова</institution><country>Belarus</country></aff><pub-date pub-type="collection"><year>2016</year></pub-date><pub-date pub-type="epub"><day>03</day><month>06</month><year>2019</year></pub-date><volume>0</volume><issue>7</issue><fpage>304</fpage><lpage>308</lpage><permissions><copyright-statement>Copyright &amp;#x00A9; Емельяненко Е.Е., Тарутин И.Г., Савков А.В., 2019</copyright-statement><copyright-year>2019</copyright-year><copyright-holder xml:lang="ru">Емельяненко Е.Е., Тарутин И.Г., Савков А.В.</copyright-holder><copyright-holder xml:lang="en">Emelyanenko E.E., Tarutin I.G., Savkov A.V.</copyright-holder><license xml:lang="ru" license-type="creative-commons-attribution" xlink:href="https://creativecommons.org/licenses/by/4.0/" xlink:type="simple"><license-p>Данная работа распространяется под лицензией Creative Commons Attribution 4.0.</license-p></license><license xml:lang="en" license-type="creative-commons-attribution" xlink:href="https://creativecommons.org/licenses/by/4.0/" xlink:type="simple"><license-p>This work is licensed under a Creative Commons Attribution 4.0 License.</license-p></license></permissions><self-uri xlink:href="https://doklady.bsuir.by/jour/article/view/784">https://doklady.bsuir.by/jour/article/view/784</self-uri><abstract><p>Представлена программа контроля качества для позитронно-эмиссионного томографа Discovery IQ. Данная программа адаптирована к определенным условиям клинической эксплуатации указанного аппарата в РНПЦ ОиМР им. Н.Н. Александрова, с учетом имеющихся возможеностей и особенностей оборудования.</p></abstract><trans-abstract xml:lang="en"><p>The quality control program for positron emission tomograph Discovery IQ is presented. The program is adapted to the specific conditions of the clinical operation of indicated equipment at the N.N. Alexandrov National Cancer Centre of Belarus, taking into account the existing features and equipment capabilities.</p></trans-abstract><kwd-group xml:lang="ru"><kwd>контроль качества</kwd><kwd>ПЭТ/КТ-сканер</kwd><kwd>фантом</kwd><kwd>стандарты</kwd><kwd>ПЭТ-центр</kwd></kwd-group><kwd-group xml:lang="en"><kwd>quality control</kwd><kwd>PET / CT scanner</kwd><kwd>a phantom</kwd><kwd>standards</kwd><kwd>PET Center</kwd></kwd-group></article-meta></front><back><ref-list><title>References</title><ref id="cit1"><label>1</label><citation-alternatives><mixed-citation xml:lang="ru">Наркевич Б.Я., Костылев В.А. Медицинская физика. М., 2008.</mixed-citation><mixed-citation xml:lang="en">Наркевич Б.Я., Костылев В.А. Медицинская физика. М., 2008.</mixed-citation></citation-alternatives></ref><ref id="cit2"><label>2</label><citation-alternatives><mixed-citation xml:lang="ru">Рудас М.С., Насникова И.Ю., Матякин Г.Г. Позитронно-эмиссионная томография в клинической практике. М., 2007.</mixed-citation><mixed-citation xml:lang="en">Рудас М.С., Насникова И.Ю., Матякин Г.Г. Позитронно-эмиссионная томография в клинической практике. М., 2007.</mixed-citation></citation-alternatives></ref><ref id="cit3"><label>3</label><citation-alternatives><mixed-citation xml:lang="ru">ГОСТ Р МЭК 61223-2-6-2001. Оценка и контроль эксплуатационных параметров рентгеновской аппаратуры в отделениях (кабинетах) рентгенодиагностики.</mixed-citation><mixed-citation xml:lang="en">ГОСТ Р МЭК 61223-2-6-2001. Оценка и контроль эксплуатационных параметров рентгеновской аппаратуры в отделениях (кабинетах) рентгенодиагностики.</mixed-citation></citation-alternatives></ref><ref id="cit4"><label>4</label><citation-alternatives><mixed-citation xml:lang="ru">International Electrotechnical Commission. Evaluation and Routine Testing in Medical Imaging Departments Geneva, 2006.</mixed-citation><mixed-citation xml:lang="en">International Electrotechnical Commission. Evaluation and Routine Testing in Medical Imaging Departments Geneva, 2006.</mixed-citation></citation-alternatives></ref><ref id="cit5"><label>5</label><citation-alternatives><mixed-citation xml:lang="ru">Тарутин И.Г., Шитиков Б.Д., Апанович В.Н. Протокол контроля качества работы аппаратов и приборов ядерной медицины.</mixed-citation><mixed-citation xml:lang="en">Тарутин И.Г., Шитиков Б.Д., Апанович В.Н. Протокол контроля качества работы аппаратов и приборов ядерной медицины.</mixed-citation></citation-alternatives></ref></ref-list><fn-group><fn fn-type="conflict"><p>The authors declare that there are no conflicts of interest present.</p></fn></fn-group></back></article>
