<?xml version="1.0" encoding="UTF-8"?>
<!DOCTYPE article PUBLIC "-//NLM//DTD JATS (Z39.96) Journal Publishing DTD v1.3 20210610//EN" "JATS-journalpublishing1-3.dtd">
<article article-type="research-article" dtd-version="1.3" xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xml:lang="ru"><front><journal-meta><journal-id journal-id-type="publisher-id">bsuir</journal-id><journal-title-group><journal-title xml:lang="ru">Доклады БГУИР</journal-title><trans-title-group xml:lang="en"><trans-title>Doklady BGUIR</trans-title></trans-title-group></journal-title-group><issn pub-type="ppub">1729-7648</issn><issn pub-type="epub">2708-0382</issn><publisher><publisher-name>БГУИР</publisher-name></publisher></journal-meta><article-meta><article-id custom-type="elpub" pub-id-type="custom">bsuir-174</article-id><article-categories><subj-group subj-group-type="heading"><subject>Research Article</subject></subj-group><subj-group subj-group-type="section-heading" xml:lang="ru"><subject>Статьи</subject></subj-group></article-categories><title-group><article-title>НЕЛИНЕЙНЫЙ АНАЛИЗ ЭЛЕКТРОМИОГРАММ ПРИ ДЕЙСТВИИ ДОЗИРОВАННОЙ ФИЗИЧЕСКОЙ НАРУЗКИ, КОФЕИНА И L-КАРНИТИНА</article-title><trans-title-group xml:lang="en"><trans-title>Nonlinear analysis of electromyograms influenced by the graduated physical load, caffeine, and L-carnitine</trans-title></trans-title-group></title-group><contrib-group><contrib contrib-type="author" corresp="yes"><name-alternatives><name name-style="eastern" xml:lang="ru"><surname>Сидоренко</surname><given-names>А. В.</given-names></name><name name-style="western" xml:lang="en"><surname>Sidorenko</surname><given-names>A. V.</given-names></name></name-alternatives><email xlink:type="simple">noemail@neicon.ru</email><xref ref-type="aff" rid="aff-1"/></contrib></contrib-group><aff xml:lang="ru" id="aff-1"><institution>Белорусский государственный университет</institution><country>Belarus</country></aff><pub-date pub-type="collection"><year>2013</year></pub-date><pub-date pub-type="epub"><day>03</day><month>06</month><year>2019</year></pub-date><volume>0</volume><issue>3</issue><fpage>58</fpage><lpage>63</lpage><permissions><copyright-statement>Copyright &amp;#x00A9; Сидоренко А.В., 2019</copyright-statement><copyright-year>2019</copyright-year><copyright-holder xml:lang="ru">Сидоренко А.В.</copyright-holder><copyright-holder xml:lang="en">Sidorenko A.V.</copyright-holder><license xml:lang="ru" license-type="creative-commons-attribution" xlink:href="https://creativecommons.org/licenses/by/4.0/" xlink:type="simple"><license-p>Данная работа распространяется под лицензией Creative Commons Attribution 4.0.</license-p></license><license xml:lang="en" license-type="creative-commons-attribution" xlink:href="https://creativecommons.org/licenses/by/4.0/" xlink:type="simple"><license-p>This work is licensed under a Creative Commons Attribution 4.0 License.</license-p></license></permissions><self-uri xlink:href="https://doklady.bsuir.by/jour/article/view/174">https://doklady.bsuir.by/jour/article/view/174</self-uri><abstract><p>Анализируются интерференционные поверхностные электромиограммы, отображающие деятельность периферической нервной системы. Использование метода задержанной координаты дает возможность объективного анализа электромиограмм, что реализуется в разработанном нами информационно-измерительном комплексе. Проводится анализ интерференционных электромиограмм дельтовидной мышцы в динамике при действии дозированной физической нагрузки, нагрузки и кофеина, нагрузки и препарата L-карнитина. Полученные количественные параметры позволяют получить информацию об активизации периферической нервной системы под влиянием комбинированного действия на организм дозированной физической нагрузки и кофеина, дозированной физической нагрузки и препарата L-карнитина в процессе увеличения нагрузки. Это подтверждается параметрами методов задержанной координаты и спектрального корреляционного анализа.</p></abstract><trans-abstract xml:lang="en"><p>The interference surface electromyograms reflecting the activity of peripheral nervous system are analyzed using the delayed coordinate analysis method. Objective analysis of electromyograms is realized with the help of the specially developed information-measuring system, including analysis of interference electromyograms of delta-muscles in dynamics influenced by the graduated physical load, combined physical load and caffeine, combined physical load and L-carnitine. The obtained quantitative parameters provide information about the increasing activity of the peripheral nervous system under the combined effect of the graduated physical load and caffeine or L-carnitine. This fact is supported by dynamics of the parameters of the delayed coordinate and spectral correlation methods.</p></trans-abstract><kwd-group xml:lang="ru"><kwd>сигналы</kwd><kwd>обработка</kwd><kwd>информация</kwd><kwd>нелинейный анализ</kwd><kwd>динамика</kwd><kwd>электромиограмма</kwd></kwd-group></article-meta></front><back><ref-list><title>References</title><ref id="cit1"><label>1</label><citation-alternatives><mixed-citation xml:lang="ru">Исаков Р.В., Кузнецов А.А., Сушкова Л.Т. Методы и средства обработки информации при оценке функционального состояния организма человека. Владимир, 2006.</mixed-citation><mixed-citation xml:lang="en">Исаков Р.В., Кузнецов А.А., Сушкова Л.Т. Методы и средства обработки информации при оценке функционального состояния организма человека. Владимир, 2006.</mixed-citation></citation-alternatives></ref><ref id="cit2"><label>2</label><citation-alternatives><mixed-citation xml:lang="ru">Сидоренко А.В. Методы информационного анализа биоэлектрических сигналов. Минск, 2003.</mixed-citation><mixed-citation xml:lang="en">Сидоренко А.В. Методы информационного анализа биоэлектрических сигналов. Минск, 2003.</mixed-citation></citation-alternatives></ref><ref id="cit3"><label>3</label><citation-alternatives><mixed-citation xml:lang="ru">Команцев В.Н., Заболотных В.В. Методические основы клинической электромиографии. СПб, 2001.</mixed-citation><mixed-citation xml:lang="en">Команцев В.Н., Заболотных В.В. Методические основы клинической электромиографии. СПб, 2001.</mixed-citation></citation-alternatives></ref><ref id="cit4"><label>4</label><citation-alternatives><mixed-citation xml:lang="ru">Сидоренко А.В., Ходулев В.И., Селицкий А.П. // Биомедицинские технологии и радиоэлектроника. 2006. № 11. С. 53-60.</mixed-citation><mixed-citation xml:lang="en">Сидоренко А.В., Ходулев В.И., Селицкий А.П. // Биомедицинские технологии и радиоэлектроника. 2006. № 11. С. 53-60.</mixed-citation></citation-alternatives></ref><ref id="cit5"><label>5</label><citation-alternatives><mixed-citation xml:lang="ru">Сидоренко А.В. // Электроника инфо. 2006. № 8. С. 62-63.</mixed-citation><mixed-citation xml:lang="en">Сидоренко А.В. // Электроника инфо. 2006. № 8. С. 62-63.</mixed-citation></citation-alternatives></ref><ref id="cit6"><label>6</label><citation-alternatives><mixed-citation xml:lang="ru">Grassberger P., Procaccia I. // Phys. Rev. Lett. 1986. V. 50. P. 483-489.</mixed-citation><mixed-citation xml:lang="en">Grassberger P., Procaccia I. // Phys. Rev. Lett. 1986. V. 50. P. 483-489.</mixed-citation></citation-alternatives></ref><ref id="cit7"><label>7</label><citation-alternatives><mixed-citation xml:lang="ru">Wiles J.D., Coleman D., Tegerdine M. et. al. // J. Sport. Sci. 2006. Vol. 24. Р. 1165-1176.</mixed-citation><mixed-citation xml:lang="en">Wiles J.D., Coleman D., Tegerdine M. et. al. // J. Sport. Sci. 2006. Vol. 24. Р. 1165-1176.</mixed-citation></citation-alternatives></ref><ref id="cit8"><label>8</label><citation-alternatives><mixed-citation xml:lang="ru">Greig C., Finch K.M., Jones D.A. // Eur. J. Appl.Physiol. Occup. Physiol. 1987. Vol. 56. № 4. P. 457-460.</mixed-citation><mixed-citation xml:lang="en">Greig C., Finch K.M., Jones D.A. // Eur. J. Appl.Physiol. Occup. Physiol. 1987. Vol. 56. № 4. P. 457-460.</mixed-citation></citation-alternatives></ref></ref-list><fn-group><fn fn-type="conflict"><p>The authors declare that there are no conflicts of interest present.</p></fn></fn-group></back></article>
